Kindly Click here and Download Our Products Brochure. Combustion Monitoring Chemicals(CMC)
| Problem |
Remedy |
| Under deposit corrosion |
ALTRET CMC increase Ash fusion temperature and reduce fouling tendency and thereby control under deposit corrosion |
| Fouling tendency |
ALTRET CMC product minimizes fouling tendency as it changes ash particle morphology & also reduceangle of repose |
| Conductivity of Ash |
ALTRET CMC increase ash conductivity and thus minimizes SPM through ESP |
| Ash Density |
Reduce as ALTRET product will changes ash particle morphology |
| CO,Nox,Sox |
Reduces due to the anti emission characteristic of ALTRET CMC |
| Unburnt |
Decrease due to the combustion catalyst effect of ALTRET CMC |
| Erosion rate |
Minimizes due to changes in ash morphology |
As you are aware, to improve the overall efficiency of boiler following two parameters need to be improved
- Combustion Efficiency
- Thermal Resistance of Heat Transfer Surfaces
Combustion efficiency is governed by fuel quality (Ash contents, Carbon, Moisture, C.V.), excess air ratio, bed height, particle size, air velocity, furnace configuration and complete oxidation of carbon.
The thermal resistance of heat transfer surfaces depends on tube material, waterside scaling, fireside fouling, particle morphology, presence of volatile and temperature gradients.
The combustion efficiency can be improved by using suitable combustion catalyst. The improved combustion will not only improve the overall efficiency but also reduce the emission level of the system. The additive CMC also alter the particle morphology, which reduces the fouling and clinkering tendency of ash by changing the eutectic structure of ash and thus the thermal efficiency is improved. |
|